1.[Info-Ingres] logstat write vs dual write
Hi Everyone, Does anyone have a strong feeling on how much attention I should be paying to discrepancies in the Log Write and Dual Log Write figures in logstat? I've always checked that these numbers are much the same - seems like a reasonable thing to do. Fact is I have a monitor program that sounds an alarm if they are more than 10 writes apart. On most of the systems I've got, I see these numbers never being more than a few writes out, and that over time they tend to always agree to a very small percentage. So my monitor very rarely pings at me. But on some hosts, the writes slowly drift further apart - generally as a result of load, and never seem to come back into agreement. The percentage difference is small, but troubling. eg. On the 5th Jan at 10:51: write complete 868522 dual write complete 868523 Now: write complete 2587889 dual write complete 2587759 The system drifted in response to heavy usage of the log file on the 5th Jan. I've checked in the OS system logs and there is no sign of a problem on the disk holding the dual log. Martin Bowes Random Duckman Quote #26: Cornfed - Duckman had been reduced to the state of a gibbering, mindless idiot. In many ways this was an improvement - but his pro country music attitude was starting to worry me.
2.[Info-Ingres] Emma McGrattan : Men Write Code from Mars, Women Write More Helpful Code from Venus
3.How can i write a log query sequence?
Hi at all! I need to write in a text file all the query that Informix applied in a database. I can do that?...and how? Tnx at all!
4.ontape could not write log tape error is coming
Hi, could not write log tape error is coming while taking ontape -c.Informix version is 7.3 tar command is working fine.In config file device entry is /dev/rct0. First the logical log backup is directed to harddisk.After DDS3-dat drive has installed. Guideme to restore the problem. tks palani
5.How to force logical log write to tape?
Presently, our Informix database logical logs is configured to write to our DLT tape library. I had this problem when changing tape in DLT Tape Library in Legato Networker. When a mounted tape in the tape library was being temporary ejected, and before it was fully ejected, and if there is any Informix log write happened. Networker would marked the tape in transit missing, and prompt for next tape, even if the "tape-in-transit" was under utilised. In order to prevent this from happening, I need to flush all the logs to tape prior to the intended tape ejecting. This would allow me more time to complete the ejecting cycle. There is no Informix database administrator in our workplace. Anyone could tell me the syntax to do so?
6. XLogWrite: write request 0/53A4000 is past end of log
7. XLogWrite: write request 0/53A4000 is past end of log 0/53A4000
Users browsing this forum: No registered users and 30 guest